Silent/manual Sensor Calibration on a P330i/ P430i

Author: NSW Service Reference Number: AA-00143 Views: 1565 Created: 2010-05-14 16:08 Last Updated: 2010-10-01 13:50 0 Rating/ Voters

Silent/manual Sensor Calibration on a P330i/ P430i

Note: This is valid for Firmware 1.17.88 and above

1. Install a colour ribbon in your printer (Use YMCKO in the P330i Printer. Or optionally a YMCKOK ribbon in a P430i)

 

2. Select Windows “Printer and Faxes”, Right mouse click on the applicable driver, then select Properties.

 

3. Select the “Device Settings” tab., Select “Tools – Properties”.

 

4. Input the manual calibration command CALB in the “Command to send to printer” field.

 

5. Select the “Execute” button (or hit the Enter on the keypad).

 

6. Wait till the printer completes the calibration process., This is indicated by the Printer LCD displaying READY.

 

 

 